Inspection IDReason for InspectionInspection DateInspection Status 
SIN-00104194 Renewal 11/29/2016 Compliant - Finalized
RegulationLIS Non-Compliance AreaCorrection RequiredPlans of CorrectionCorrection DatePOC Status
6400.113(c)Individual #2 was not included in the list of individuals attending the fire safety training on 9/12/16. A written record of fire safety training, including the content of the training and a list of the individuals attending, shall be kept.The Program Specialist and Fire Safety Trainer were able to verify Individual #2's presence and the marking on the page that is his signature. They have signed off on this and verification will be sent to the department as immediate correction. The development department has reviewed through the remaining group home sign in sheets for fire safety training and has compliance for all individuals. All training documentation will be submitted to the training department for review of attendance and compliance. Quarterly audits of the training files will be completed for the year to ensure all individuals receive this training annually and all signatures are verified on the attendance sign in. [Documentation of the audits shall be kept. (AS 12/20/16)] 12/19/2016 Implemented
SIN-00072502 Renewal 12/02/2014 Compliant - Finalized
RegulationLIS Non-Compliance AreaCorrection RequiredPlans of CorrectionCorrection DatePOC Status
6400.33(e)Individual #1's bedroom has an audio monitor; Individual #1 cannot independently turn the monitor on or off.An individual has the right to privacy in bedrooms, bathrooms and during personal care. The Audio Monitor was removed from The bedroom for client #1. 12/29/2014 Implemented
6400.68(b)The hot water temperature in the bathtub located in the large bathroom was 122.3 degrees Fahrenheit at 12:00 PM. Hot water temperatures in bathtubs and showers may not exceed 120°F. The mixing valve for the hot water tank was not properly regulating the water temperature. The Maintenance Manager purchased a replacement mixing valve on 12/16/2014 and installed it on 12/17/14. The water temperature will be taken daily by an assigned staff member in Rockwood and all group homes licensed by 6400 regulations. The staff member at Rockwood and all group homes will notify the EHCA maintenace worker and the Program Specialist if the water temperature exceeds the required temperature of 120 degrees. Maintenance will address the issue and ensure the water temperature is under 120 degrees. The Program Specialist will review the water temperature log each shift he/she works to ensure that is being completed accurately and thoroughly and that any issues with the water temperature are corrected. 12/29/2014 Implemented
6400.103The written emergency evacuation procedures do not include the means of transportation.There shall be written emergency evacuation procedures that include individual and staff responsibilities, means of transportation and an emergency shelter location. The Quality Assurance Director revised the Emergency Evacuation Plan on 12/24/14 to include that the means of transportation will be by Agency and Staff vehicles and that the emergency shelter location are the Avalon Hotel on 16 West 10th Street, Erie, PA 16501, client family member's, or staff member's homes. The revised Emergency Evacuation Plan will be distributed to all group homes by January 1, 2015. 12/29/2014 Implemented
6400.106The furnace has not been inspected and cleaned for several years by a professional furnace cleaning company or trained staff person.Furnaces shall be inspected and cleaned at least annually by a professional furnace cleaning company. Written documentation of the inspection and cleaning shall be kept. The Maintenance Manager will schedule the furnace cleaning and inspection with a professional cleaning company by January 16, 2015. The Maintenance Manager will schedule the cleaning and inspections to be done by a professional cleaning company annually. The Program Specialist will receive a copy of the cleaning and inspection reports to ensure they were done by the professionally cleaning company annually. 12/29/2014 Implemented
SIN-00203099 Renewal 04/05/2022 Compliant - Finalized
SIN-00165385 Renewal 10/31/2019 Compliant - Finalized